Wireless, non-contact resonance frequency analysis at chairside. Instant ISQ value from 1 to 99. Color-coded stability classification. Developed by Dentis using evidence-based RFA technology.
Every feature is designed to give you confidence at the point of decision — from placement to final loading.
Evidence-based RFA (resonance frequency analysis) technology. Non-contact measurement means zero disruption to the healing implant. ISQ accuracy of ±1 ensures clinically reliable readings every time.
ISQ value shown instantly on the OLED display with color classification. High (70–99) in green, Medium (60–69) in orange, Low (1–59) in red. Previous and current measurements displayed simultaneously.
Fully wireless — no cables during use. Automatic measurement mode activates the moment the PEG is detected. Power-saving mode extends battery life between charges. Simple single-button operation.
Internal lithium polymer battery (550mAh) is user-replaceable — no device disposal needed. The titanium ChecQ PEG Driver maintains its shape and measurement value even after repeated clinical use.
Developed by Dentis Co., Ltd. using proprietary RFA technology refined through years of clinical data. The device's resonance frequency measurement detects microscopic changes in implant stability — far more sensitive than tactile assessment alone.
The ChecQ PEG is machined from titanium for dimensional stability. Unlike generic RFA pegs, the ChecQ PEG will not deform or drift in measurement value across repeated uses — giving you consistent baseline data across patient visits.
Four simple steps. No contact with the implant required. Measurement completes automatically when the device detects the PEG.
Screw the titanium ChecQ PEG Driver onto the implant at the time of stability assessment. The PEG is reusable and maintains its shape and measurement value even after multiple uses.
Press the power button to turn on ChecQ. Hold the wand tip 2–3mm from the PEG at approximately 45°. No contact with implant, soft tissue, or surrounding structures required.
ChecQ automatically detects the PEG and switches into measurement mode. The device transmits a resonance frequency signal and calculates the ISQ value within seconds.
The ISQ value appears on the display alongside a color-coded stability classification. Previous measurement values are also shown for direct comparison. Use Mode button for manual measurement override.
Complete technical specifications from the official ChecQ product leaflet. Ref: D-L-CQ-V1-202406-ENG · ©2024 DENTIS Co., Ltd.
| Component | Parameter | Specification | Note |
|---|---|---|---|
| Main Body | ISQ Measuring Range | 1 – 99 | Accuracy: ISQ ±1 |
| Stability Display | Below 60: Low · 60–69: Medium · Above 70: High | Color-coded LED | |
| Battery Type | Lithium Polymer · DC 3.7V · 550mAh | Replaceable | |
| Charging Time | 3 hours | — | |
| Weight | 70g | — | |
| Dimensions | 226 × 25 × 26mm | — | |
| Charging Stand | Weight | 73g | — |
| Dimensions | 106 × 82 × 45mm | — | |
| Adapter | Rated Input | AC 100–240V · 50/60Hz | Universal |
| Rated Output | DC 5V · 2A | — | |
| Weight | 130g | — | |
| Dimensions | 78 × 46 × 80mm · Cable 1,525mm | — | |
| Demo PEG | Weight | 14g | — |
| Dimensions | 20 × 20 × 39mm | — | |
| ChecQ PEG Driver | Material | Titanium | Reusable |
| Weight / Dimensions | 1g · 5 × 5 × 15mm | — |
ChecQ handpiece device with OLED display, mode button, and power button. 226 × 25 × 26mm · 70g
Desktop charging cradle for the ChecQ handpiece. 106 × 82 × 45mm · 73g
AC 100–240V input, DC 5V 2A output. 78 × 46 × 80mm. Cable length 1,525mm
Demonstration PEG for training and clinic display. 20 × 20 × 39mm · 14g
Titanium implant PEG for clinical measurement. Reusable. 5 × 5 × 15mm · 1g
Complete clinical and technical user guide for proper operation and maintenance of the ChecQ device
Contact Digiscope for Philippine pricing, demo availability, and clinical training on the ChecQ RFA device.
Our representative will contact you within 24 hours to arrange a chairside demo and provide Philippine pricing.